§ Programming the receiver’s synthesizers (setting the operating frequency)
§ Selecting gain control modes
o Automatic Gain Control (AGC)
o Manual Gain Control (MGC)
o High Gain Mode
Configuring MGC Level
Placing the receiver in sleep mode
Selecting frequency reference
o Internal Reference
o External Reference
Selecting the IF Bandwidth
o 500 kHz
o 1 MHz
o 1.5 MHz
o 2 MHz
o 10 MHz
System Parameter |
Specification |
IF Output Level: MGC AGC MGC High Gain Mode AGC High Gain Mode |
-20 dBm typical with -100 dBm applied to RF Input (all attenuators set to minimum attenuation) -20 dBm typical 0 dBm typical with -100 dBm applied to RF Input (all attenuators set to minimum attenuation) 0 dBm typical |
Gain: Normal Mode High Gain Mode |
80 dB typical 100 dB typical [Units can be gain leveled to ± 2dB across entire frequency range – Consult Factory] |
IF Bandwidth |
User Selectable: 500 kHz, 1 MHz, 1.5 MHz, 2 MHz, 10 MHz |
IF Rejection |
80 dB (100 dB typical) |
Image Rejection: 200 – 500 MHz 500 – 1300 MHz 1300 – 1800 MHz 1800 – 2500 MHz |
100 dB typical 80 dB typical 68 dB typical 80 dB typical |
3 dB Bandwidth: 200 – 500 MHz 500 – 1300 MHz 1300 – 1800 MHz 1800 – 2500 MHz |
5% BW typical 8% BW typical 4% BW typical 3% BW typical |
10 dB Bandwidth: 200 – 500 MHz 500 – 1300 MHz 1300 – 1800 MHz 1800 – 2500 MHz |
9% BW typical 15% BW typical 7% BW typical 6% BW typical |
20 dB Bandwidth: 200 – 500 MHz 500 – 1300 MHz 1300 – 1800 MHz 1800 – 2500 MHz |
13% BW typical 23% BW typical 11% BW typical 9% BW typical |